Solved Aging Dam Dilemma

How Computational Fluid Dynamics Modeling Solved Aging Dam Dilemma

By AyresApril 6, 2021No Comments

Solved Aging Dam Dilemma
Solved Aging Dam Dilemma

Keyword : 3D Hydraulic Modeling,CFD, CFD Model, Computational Fluid Dynamics, Dam Hydraulics, Hydrology structure damage

급격한 변화나 예기치 못한 노후화로 인해 댐에서 복잡한 문제가 발생하는 경우 20세기에 개발된 산업 표준 설계 방정식과 방법론이 많은 경우 올바른 솔루션을 제공할 수는 없습니다. 다행스럽게도 엔지니어들은 적절한 조치나 수리를 적용할 수 있도록 유압 상황을 확인하기 위해 전산유체역학(CFD) 모델을 사용할 수 있게 되었습니다.

About the Expert:

Matthew Hickox, PE, brings civil engineering expertise in stormwater and river design, planning, and construction phase services. His experience is founded on a solid understanding of hydrologic modeling, 1- and 2-dimensional hydraulic modeling, in-stream hydraulic structures, scour protection measures, culvert and bridge hydraulics, and the regulatory environment for stormwater projects.

How Does CFD Work in Practice?

최근의 한 사례에서 하천 수문학 및 지형학은 낮은 수두 전환 댐 주변에서 변경되었습니다. 지난 수십 년 동안 빠르게 발전해 온 도시 지역의 하류에 있는 모래 바닥 하천 시스템에 위치한 댐의 문제는 주변 하천 시스템에서 일어나는 여러 가지 일들로 인해 복잡해졌습니다. 증가하는 도시화는 배출 빈도를 증가시켰을 뿐만 아니라 기본 흐름을 증가시켰습니다. 수리학적으로 가파른 시스템은 일시적인 지류에서 연간 베이스 흐름으로의 변화가 상류가 침식됨에 따라 퇴적물 부하도 증가했음을 의미했습니다.

이 조합은 전환 댐의 하류 수로가 지난 15년 동안 3-4피트 감소했고, 배수가 감소된 정수장 apron에서 속도가 증가했으며 구조물 표면에 마모를 유발하는 퇴적물 하중이 감소했음을 의미합니다. 이러한 문제 중 어느 것도 전환 댐의 원래 설계의 잘못이 아니었지만 변화하는 하천 수문 및 지형학으로 인해 원래 설계자가 예상하지 못한 조건이 발생했습니다.

기존 구조물의 단위 너비 CFD 모델은 기존 현장 조건으로 인해 정수기 계류장에 수압 점프가 형성되지 않았다는 현장 관찰을 확인했습니다. 1).

Figure 1. Existing conditions unit width CFD model results showing velocity, cross section view of structure.
Figure 1. Existing conditions unit width CFD model results showing velocity, cross section view of structure.

설계 표고(열화 전)에서 하류 하류 바닥 표고와 함께 개발된 유사한 단위 너비 CFD 모델은 원래 설계가 정수 유역 계류장과 배수로 전면 근처에서 수압 점프를 생성한다는 것을 보여주었습니다. 이 단위 너비 CFD 모델은 구조에 영향을 미치는 수력학의 가치 있는 검증을 제공하지만 구조 손상이 구조 중간에서 매우 뚜렷하고 다른 영역에서는 거의 손대지 않았기 때문에 이것만으로는 충분하지 않습니다. (그림 2)

Figure 2. Original design conditions unit width CFD model results showing velocity, cross section view of structure. The only difference with Figure 1 is the downstream bed elevation.
Figure 2. Original design conditions unit width CFD model results showing velocity, cross section view of structure. The only difference with Figure 1 is the downstream bed elevation.

전체 기존 조건 CFD 모델은 정수조 앞치마 마모의 범위와 그에 따른 손상을 확인했습니다. (그림 3 및 4)

Figure 3. Existing conditions CFD model results showing velocity streamlines at 2-year event discharge. High velocities are areas of significant abrasion damage, low velocity areas have little or no abrasion damage.
Figure 3. Existing conditions CFD model results showing velocity streamlines at 2-year event discharge. High velocities are areas of significant abrasion damage, low velocity areas have little or no abrasion damage.
Figure 4. Existing conditions shows rebar exposed from significant abrasion damage to stilling basin apron in high velocity areas
Figure 4. Existing conditions shows rebar exposed from significant abrasion damage to stilling basin apron in high velocity areas

이 구조물에 대한 수리를 위한 예비 설계 동안 간단한 분석에 따르면 구조물의 미수를 높이는 것이 방수로 토우 근처의 구조물에 수력학적 점프를 만드는 데 도움이 될 것이며, 이는 정수 유역 계류장과 계류장을 가로지르는 극한 속도를 감소시킬 것입니다. 따라서 구조의 마모를 크게 줄입니다(그림 5 참조). 이 예비 제안 조건 CFD 모델은 엔드 실 높이만 높였습니다. 구조물 하류의 하천 시스템의 상태와 지형은 나머지 설계 수명 동안 구조물의 안정성을 보장하기 위해 모든 최종 설계 조건에 대해 평가되어야 합니다.

Figure 5. Preliminary design check to verify velocities under a raised tailwater condition at a 2-year event discharge. Velocity cross section slices shown.
Figure 5. Preliminary design check to verify velocities under a raised tailwater condition at a 2-year event discharge. Velocity cross section slices shown.

CFD 모델은 설계 상황이 확립된 설계 방정식 및 절차의 한계 내에 깔끔하게 속하지 않을 때 유압을 확인하는 또 다른 도구를 제공합니다. 구조와 유역의 개요에 대해 자세히 설명하는 전체적인 관점은 프로젝트 현장의 현재와 미래의 상태를 평가하는 데 필요합니다. 이 예에서 구조의 설계 및 작동은 원래 설계와 매우 유사하게 유지됩니다. 구조 주변에서 변경된 것은 하천 시스템입니다. CFD는 현장 조건 변경으로 인해 예기치 않은 수리력 및 구조 손상이 발생할 때 복잡한 수리력을 분석할 수 있는 도구 상자의 또 다른 도구를 제공합니다.

CFD 또는 여기 Ayres에서 제공하는 유압 엔지니어링 서비스에 대한 자세한 내용은 Matthew Hickox, PE에게 문의하십시오.